Questions? 800-523-5874 | [email protected]
LiteFix is an off-white, two component acrylic mounting system. Acrylics are easy-to-use resins with short curing times and negligible shrinkage. They consist of self-polymerizing components that harden with the addition of catalyst. Hardened acrylic is thermoplastic and resistant to most chemicals.
The ratio for LiteFix Powder: LiteFix Liquid is 20:10 by weight and 20:10 by volume. Weighing is recommended to obtain the best mounts and for reproducibility
Note: Do not pour excess liquid back into the bottle, as this will significantly reduce the shelf life.
All EMS mounting cups can be used. If possible, choose a mounting cup where the distance between the specimen and cup wall is approx. 5 mm/0.2".
To promote the best possible adhesion of LiteFix to the specimen, ensure that the specimen is thoroughly cleaned and dry prior to mounting. Each surface must be free from grease, moisture and other contaminants.
LiteFix is a room temperature curing system. For a 30 mm / 1¼" dia. mount, the curing time is approx. 20 minutes. We recommend keeping the mount in the mounting cup until the temperature is below 40°C/104°F.
After removal from the mounting cup, the mount is immediately ready for preparation.
Components | Ratio by Weight | Ratio by Volume |
LiteFix Powder | 20 | 20 |
LiteFix Liquid | 10 | 10 |
LiteFix Powder | 0.95 g/mL |
LiteFix Liquid | 0.97 g/mL |
Can be prepared (ground and polished) after | 20 minutes |
Peak temperature * | 75°C/167°F |
Pot life after mixing | 3½ min |
LiteFix Liquid is soluble in Acetone
The filling material in LiteFix is calcium carbonate
Hardness | 84 Shore D |
Density | 1.4 g/mL |
Chemical Resistance | LiteFix is resistant to the most common etching materials but can be colored |