Place grids on drops of the enhancement mixture arrayed on a sheet of Parafilm™.
Incubate specimens (e.g. vibratome sections) in Petri dishes or Eppendorf tubes containing the enhancement mixture, with agitation. When enhancement is completed, the specimens are washed with distilled water. A fixation step with photographic fixer is not required.
The AURION R-GENT SE-LM components are stored at 4°C and allowed to reach room temperature before use. SE-EM INITIATOR may be stored at -20°C for prolonged shelf life.
A few drops of the freshly prepared enhancement mixture are applied to cover the specimen. During enhancement the specimens are kept in a moist chamber. The ongoing enhancement may at intervals be monitored with an inverted light microscope. When enhancement is judged to be complete, the specimens are washed with distilled water. A fixation step with photographic fixer is not required.
Specimens like floating (vibratome) sections can be enhanced in Petri dishes or 6-24 well plates.
Depending on the type of assay the enhancement for bio assays can be performed in sealed plastic bags, Petri dishes or in disposable screw cap sealed tubes.
For additional information please see the Aurion Immunogold Newsletter and Protocol sections