EMS 4880 3/4 Hp Recirculating Heater/Chiller

E4800 Recirculating Heater/Chillers

Recommended for open and closed loop applications, offering simplicity, reliability and quiet operation. The range includes the E4860, 4870, 4880 and 4890.

Features

  • Precise temperature control
  • Quiet, efficient operation
  • Proven reliability
  • Low maintenance
  • Environmentally friendly - avoids running water to waste

Some typical applications

  • Vacuum coating equipment
  • Critical point dryers including the E3100
  • Electron microscopes
  • Chromatography equipment
  • Electrophoresis baths
  • Environmental chambers
  • Crystal growth apparatus
  • Fermentation equipment
  • Interferometers
  • Photographic baths
  • X-ray equipment
  • Polarimeters, refractometers and many others

Temperature control

Many instruments measuring physical properties depend on accurate control of temperature and in some processes optimum temperature is essential. With the E4800 series, over-cooling (which affects efficiency) is prevented and the water temperature can be accurately controlled over the range -10 to +60°C.

A commonly misunderstood feature of refrigerated systems is in applications where the control temperature is other than at or near room temperature. When the instruments are to be operated at controlled temperatures below ambient, the extraction deteriorates significantly and, as a guide, the compounded change is 4% per degree Celsius. In practice, the refrigerant gas pressure has to be adjusted to optimize the performance at any particular temperature. However, the E4800 series incorporate automatic adjustment valves in the systems.

The E4800 series are "closed loop" and efficiencies are dramatically improved compared with open bath models. They are simple to set up and to operate, and essentially maintenance free.

Choosing the correct heater/chiller

In order to optimize performance from a heater/chiller system, the correct specification must be selected for a particular application. To cool or heat any instrument or system it is important to obtain the following information from the manufacturer:

  • Heat load to be dissipated to water, for an electron microscope: diffusion pump heater, lenses, etc
  • Flow rate and size of tubing
  • Minimum pressure

With this information, consult the Specifications below and select the appropriate heater/chiller. The basic heat load calculation formula is as follows:

Flow rate x weight of fluid x specific heat x D T = Heat Extraction.

Specifications

Heat Extraction Rates (in Watts) - 20°C - 10°C 0°C +10°C + 20°C
E4880 200W 425W 700W 1.6kW 2.2kW
4.5kW Recirculator 700W 1kW 2kW 3kW 4.5kW
6kW Recirculator 800W 1.3kW 2.6kW 4.5kW 6kW

 

Model E4880
Extraction rate at 20°C 2.2kW
Temperature range -20°C to +70°C
Refrigeration (HP) 3/4
Heater rating 2.5kW
Max pump flow 900L/h
275Gal/hr
Tank capacity 2.3L
Max pump pressure psi/bar 60psi
1.5/3bar
Height 50cm
Width 45cm
Depth 62cm
Weight 70kg
Water connections 16mm hose or 1/8 BSP
Temperature sensor R.T. Probe

Optional Attachments

  • High pressure pump for E4860 and E4870 (standard in E4880 and E4890)
  • Water failure alarm
  • Over and under temperature cut out
    NOTE: Larger capacity heater/chillers (6kW and 12kW) are available on request - please contact us for further information
  • Custom-made heater/chiller units
SKU: E4880
Pack: Each
Please request a quote for this item. Click the "Q" graphic or "Add to Quote".